EN 10028-2 Grade P295GH normalized or normalized formed (+N)

EN 10028-2 Grade P295GH normalized or normalized formed (+N) introduction

Non-alloy heat-resistant steel for steam boiler and pressure vessel construction.
Max. application temp.: approx. 400 °C

Equivalent material: IS SPV315, IS SGV410, IS SGV450, IS SGV480, KS SPPV315, ASTM A414 Grade E, ASTM A414 Grade F, ASTM A515 Grade 70, UNS K02704, UNS K03101, UNS K03102, DIN P295GH, AFNOR A48-AP, AFNOR A48-CP, BS Gr.224, GOST 14G2, IS P13, UNI Fe510-1KG, UNI FeE295, ÖNORM 17Mn4KW, UNE A47RC1/RAII, ASTM Grade 65, ASTM Grade 70, DIN 17Mn4, IS P295GH, DIN HIV, DIN 1.0481, EN 1.0481, EN 17Mn4, AFNOR A48CP, AFNOR P295GH, UNE A47RCI, BS 430, BS P295GH, JIS SG365, JIS SGV410, JIS SGV450, JIS SGV480, JIS SPV315, JIS STB510, JIS SPV32, ISO P295GH, ISO PT490, ASTM Grade C, UNS K03501, UNS K02203

EN 10028-2 Grade P295GH normalized or normalized formed (+N) general

Property Temperature Value Condition Related Standards Shape
Density 20 °C Density of 7.83 g/cm³ normalized or normalized formed (+N) EN 10028-2 Flat
- 20 °C Density of 7.83 - 7.84 g/cm³ normalized or normalized formed (+N) EN 10028-2 Flat
- 20 °C Density of 7.84 g/cm³ normalized or normalized formed (+N) EN 10028-2 Flat

EN 10028-2 Grade P295GH normalized or normalized formed (+N) thermal

Property Temperature Value Condition Related Standards Shape Comment
Coefficient of thermal expansion -100 °C Coefficient of thermal expansion of 1.08e-05 1/K normalized or normalized formed (+N) EN 10028-2 Flat -
- 20 °C Coefficient of thermal expansion of 1.19e-05 1/K normalized or normalized formed (+N) EN 10028-2 Flat -
- 100 °C Coefficient of thermal expansion of 1.22e-05 1/K normalized or normalized formed (+N) EN 10028-2 Flat -
- 100 °C Coefficient of thermal expansion of 1.22e-05 - 1.25e-05 1/K normalized or normalized formed (+N) EN 10028-2 Flat -
- 100 °C Coefficient of thermal expansion of 1.25e-05 1/K normalized or normalized formed (+N) EN 10028-2 Flat -
- 200 °C Coefficient of thermal expansion of 1.29e-05 1/K normalized or normalized formed (+N) EN 10028-2 Flat -
- 200 °C Coefficient of thermal expansion of 1.29e-05 - 1.3e-05 1/K normalized or normalized formed (+N) EN 10028-2 Flat -
- 200 °C Coefficient of thermal expansion of 1.3e-05 1/K normalized or normalized formed (+N) EN 10028-2 Flat -
- 300 °C Coefficient of thermal expansion of 1.34e-05 1/K normalized or normalized formed (+N) EN 10028-2 Flat -
- 300 °C Coefficient of thermal expansion of 1.34e-05 - 1.36e-05 1/K normalized or normalized formed (+N) EN 10028-2 Flat -
- 300 °C Coefficient of thermal expansion of 1.36e-05 1/K normalized or normalized formed (+N) EN 10028-2 Flat -
- 400 °C Coefficient of thermal expansion of 1.4e-05 1/K normalized or normalized formed (+N) EN 10028-2 Flat -
- 400 °C Coefficient of thermal expansion of 1.4e-05 - 1.41e-05 1/K normalized or normalized formed (+N) EN 10028-2 Flat -
- 400 °C Coefficient of thermal expansion of 1.41e-05 1/K normalized or normalized formed (+N) EN 10028-2 Flat -
- 500 °C Coefficient of thermal expansion of 1.43e-05 1/K normalized or normalized formed (+N) EN 10028-2 Flat -
- 500 °C Coefficient of thermal expansion of 1.43e-05 - 1.45e-05 1/K normalized or normalized formed (+N) EN 10028-2 Flat -
- 500 °C Coefficient of thermal expansion of 1.45e-05 1/K normalized or normalized formed (+N) EN 10028-2 Flat -
- 600 °C Coefficient of thermal expansion of 1.46e-05 1/K normalized or normalized formed (+N) EN 10028-2 Flat -
- 600 °C Coefficient of thermal expansion of 1.46e-05 - 1.49e-05 1/K normalized or normalized formed (+N) EN 10028-2 Flat -
- 600 °C Coefficient of thermal expansion of 1.49e-05 1/K normalized or normalized formed (+N) EN 10028-2 Flat -
Max service temperature - Max service temperature of 20 - 400 °C normalized or normalized formed (+N) EN 10028-2 Flat Long
- - Max service temperature of 400 °C normalized or normalized formed (+N) EN 10028-2 Flat Long
- - Max service temperature of 500 °C - - - Typical for Carbon Steel
Melting point - Melting point of 1480 - 1526 °C - - - Typical for Low Carbon Steel
Specific heat capacity -100 °C Specific heat capacity of 423 J/(kg·K) normalized or normalized formed (+N) EN 10028-2 Flat -
- 20 °C Specific heat capacity of 430 J/(kg·K) normalized or normalized formed (+N) EN 10028-2 Flat -
- 20 °C Specific heat capacity of 430 - 461 J/(kg·K) normalized or normalized formed (+N) EN 10028-2 Flat -
- 20 °C Specific heat capacity of 461 J/(kg·K) normalized or normalized formed (+N) EN 10028-2 Flat -
- 100 °C Specific heat capacity of 479 - 500 J/(kg·K) normalized or normalized formed (+N) EN 10028-2 Flat -
- 100 °C Specific heat capacity of 479 J/(kg·K) normalized or normalized formed (+N) EN 10028-2 Flat -
- 100 °C Specific heat capacity of 500 J/(kg·K) normalized or normalized formed (+N) EN 10028-2 Flat -
- 200 °C Specific heat capacity of 499 - 540 J/(kg·K) normalized or normalized formed (+N) EN 10028-2 Flat -
- 200 °C Specific heat capacity of 499 J/(kg·K) normalized or normalized formed (+N) EN 10028-2 Flat -
- 200 °C Specific heat capacity of 540 J/(kg·K) normalized or normalized formed (+N) EN 10028-2 Flat -
- 300 °C Specific heat capacity of 517 - 580 J/(kg·K) normalized or normalized formed (+N) EN 10028-2 Flat -
- 300 °C Specific heat capacity of 517 J/(kg·K) normalized or normalized formed (+N) EN 10028-2 Flat -
- 300 °C Specific heat capacity of 580 J/(kg·K) normalized or normalized formed (+N) EN 10028-2 Flat -
- 400 °C Specific heat capacity of 536 - 620 J/(kg·K) normalized or normalized formed (+N) EN 10028-2 Flat -
- 400 °C Specific heat capacity of 536 J/(kg·K) normalized or normalized formed (+N) EN 10028-2 Flat -
- 400 °C Specific heat capacity of 620 J/(kg·K) normalized or normalized formed (+N) EN 10028-2 Flat -
- 500 °C Specific heat capacity of 558 - 690 J/(kg·K) normalized or normalized formed (+N) EN 10028-2 Flat -
- 500 °C Specific heat capacity of 558 J/(kg·K) normalized or normalized formed (+N) EN 10028-2 Flat -
- 500 °C Specific heat capacity of 690 J/(kg·K) normalized or normalized formed (+N) EN 10028-2 Flat -
- 600 °C Specific heat capacity of 587 - 780 J/(kg·K) normalized or normalized formed (+N) EN 10028-2 Flat -
- 600 °C Specific heat capacity of 587 J/(kg·K) normalized or normalized formed (+N) EN 10028-2 Flat -
- 600 °C Specific heat capacity of 780 J/(kg·K) normalized or normalized formed (+N) EN 10028-2 Flat -
Thermal conductivity 20 °C Thermal conductivity of 46.5 - 47 W/(m·K) normalized or normalized formed (+N) EN 10028-2 Flat -
- 20 °C Thermal conductivity of 46.5 W/(m·K) normalized or normalized formed (+N) EN 10028-2 Flat -
- 20 °C Thermal conductivity of 47 W/(m·K) normalized or normalized formed (+N) EN 10028-2 Flat -
- 100 °C Thermal conductivity of 47 W/(m·K) normalized or normalized formed (+N) EN 10028-2 Flat -
- 100 °C Thermal conductivity of 47 - 47.2 W/(m·K) normalized or normalized formed (+N) EN 10028-2 Flat -
- 100 °C Thermal conductivity of 47.2 W/(m·K) normalized or normalized formed (+N) EN 10028-2 Flat -
- 200 °C Thermal conductivity of 45.9 - 46 W/(m·K) normalized or normalized formed (+N) EN 10028-2 Flat -
- 200 °C Thermal conductivity of 45.9 W/(m·K) normalized or normalized formed (+N) EN 10028-2 Flat -
- 200 °C Thermal conductivity of 46 W/(m·K) normalized or normalized formed (+N) EN 10028-2 Flat -
- 300 °C Thermal conductivity of 43.5 - 44 W/(m·K) normalized or normalized formed (+N) EN 10028-2 Flat -
- 300 °C Thermal conductivity of 43.5 W/(m·K) normalized or normalized formed (+N) EN 10028-2 Flat -
- 300 °C Thermal conductivity of 44 W/(m·K) normalized or normalized formed (+N) EN 10028-2 Flat -
- 400 °C Thermal conductivity of 40.9 - 41 W/(m·K) normalized or normalized formed (+N) EN 10028-2 Flat -
- 400 °C Thermal conductivity of 40.9 W/(m·K) normalized or normalized formed (+N) EN 10028-2 Flat -
- 400 °C Thermal conductivity of 41 W/(m·K) normalized or normalized formed (+N) EN 10028-2 Flat -
- 500 °C Thermal conductivity of 38 W/(m·K) normalized or normalized formed (+N) EN 10028-2 Flat -
- 500 °C Thermal conductivity of 38 - 38.1 W/(m·K) normalized or normalized formed (+N) EN 10028-2 Flat -
- 500 °C Thermal conductivity of 38.1 W/(m·K) normalized or normalized formed (+N) EN 10028-2 Flat -
- 600 °C Thermal conductivity of 35 W/(m·K) normalized or normalized formed (+N) EN 10028-2 Flat -
- 600 °C Thermal conductivity of 35 - 35.3 W/(m·K) normalized or normalized formed (+N) EN 10028-2 Flat -
- 600 °C Thermal conductivity of 35.3 W/(m·K) normalized or normalized formed (+N) EN 10028-2 Flat -
Thermal diffusivity 20 °C Thermal diffusivity of 12.9 mm²/s normalized or normalized formed (+N) EN 10028-2 Flat -
- 100 °C Thermal diffusivity of 12.2 mm²/s normalized or normalized formed (+N) EN 10028-2 Flat -
- 200 °C Thermal diffusivity of 11.1 mm²/s normalized or normalized formed (+N) EN 10028-2 Flat -
- 300 °C Thermal diffusivity of 9.9 mm²/s normalized or normalized formed (+N) EN 10028-2 Flat -
- 400 °C Thermal diffusivity of 8.7 mm²/s normalized or normalized formed (+N) EN 10028-2 Flat -
- 500 °C Thermal diffusivity of 7.3 mm²/s normalized or normalized formed (+N) EN 10028-2 Flat -
- 600 °C Thermal diffusivity of 5.9 mm²/s normalized or normalized formed (+N) EN 10028-2 Flat -

EN 10028-2 Grade P295GH normalized or normalized formed (+N) chemical

Property Value Condition Related Standards Shape
Aluminium Aluminium of 0.02 % normalized or normalized formed (+N) EN 10028-2 Flat
Carbon Carbon of 0.08 - 0.2 % normalized or normalized formed (+N) EN 10028-2 Flat
Chromium Chromium of 0.3 % normalized or normalized formed (+N) EN 10028-2 Flat
Copper Copper of 0.3 % normalized or normalized formed (+N) EN 10028-2 Flat
Manganese Manganese of 0.9 - 1.5 % normalized or normalized formed (+N) EN 10028-2 Flat
Molybdenum Molybdenum of 0.08 % normalized or normalized formed (+N) EN 10028-2 Flat
Nickel Nickel of 0.3 % normalized or normalized formed (+N) EN 10028-2 Flat
Niobium Niobium of 0.02 % normalized or normalized formed (+N) EN 10028-2 Flat
Nitrogen Nitrogen of 0.012 % normalized or normalized formed (+N) EN 10028-2 Flat
Phosphorus Phosphorus of 0.025 % normalized or normalized formed (+N) EN 10028-2 Flat
Silicon Silicon of 0.4 % normalized or normalized formed (+N) EN 10028-2 Flat
Sulfur Sulfur of 0.01 % normalized or normalized formed (+N) EN 10028-2 Flat
- Sulfur of 0.015 % normalized or normalized formed (+N) EN 10028-2 Flat
Titanium Titanium of 0.03 % normalized or normalized formed (+N) EN 10028-2 Flat
Vanadium Vanadium of 0.02 % normalized or normalized formed (+N) EN 10028-2 Flat

EN 10028-2 Grade P295GH normalized or normalized formed (+N) magnetic

Property Value Comment
Curie temperature Curie temperature of 770 °C Typical for Low Carbon Steel

EN 10028-2 Grade P295GH normalized or normalized formed (+N) electrical

Property Temperature Value Condition Related Standards Shape Comment
Electrical conductivity - Electrical conductivity of 6 S/m - - - Predicted Value
Electrical resistivity 20 °C Electrical resistivity of 2.2e-07 Ω·m normalized or normalized formed (+N) EN 10028-2 Flat -
- 20 °C Electrical resistivity of 2.2e-07 - 2.24e-07 Ω·m normalized or normalized formed (+N) EN 10028-2 Flat -
- 20 °C Electrical resistivity of 2.24e-07 Ω·m normalized or normalized formed (+N) EN 10028-2 Flat -
- 100 °C Electrical resistivity of 2.7e-07 Ω·m normalized or normalized formed (+N) EN 10028-2 Flat -
- 100 °C Electrical resistivity of 2.7e-07 - 2.71e-07 Ω·m normalized or normalized formed (+N) EN 10028-2 Flat -
- 100 °C Electrical resistivity of 2.71e-07 Ω·m normalized or normalized formed (+N) EN 10028-2 Flat -
- 200 °C Electrical resistivity of 3.4e-07 Ω·m normalized or normalized formed (+N) EN 10028-2 Flat -
- 200 °C Electrical resistivity of 3.4e-07 - 3.44e-07 Ω·m normalized or normalized formed (+N) EN 10028-2 Flat -
- 200 °C Electrical resistivity of 3.44e-07 Ω·m normalized or normalized formed (+N) EN 10028-2 Flat -
- 300 °C Electrical resistivity of 4.3e-07 Ω·m normalized or normalized formed (+N) EN 10028-2 Flat -
- 300 °C Electrical resistivity of 4.3e-07 - 4.31e-07 Ω·m normalized or normalized formed (+N) EN 10028-2 Flat -
- 300 °C Electrical resistivity of 4.31e-07 Ω·m normalized or normalized formed (+N) EN 10028-2 Flat -
- 400 °C Electrical resistivity of 5.3e-07 Ω·m normalized or normalized formed (+N) EN 10028-2 Flat -
- 400 °C Electrical resistivity of 5.3e-07 - 5.32e-07 Ω·m normalized or normalized formed (+N) EN 10028-2 Flat -
- 400 °C Electrical resistivity of 5.32e-07 Ω·m normalized or normalized formed (+N) EN 10028-2 Flat -
- 500 °C Electrical resistivity of 6.5e-07 Ω·m normalized or normalized formed (+N) EN 10028-2 Flat -
- 600 °C Electrical resistivity of 7.86e-07 - 7.9e-07 Ω·m normalized or normalized formed (+N) EN 10028-2 Flat -
- 600 °C Electrical resistivity of 7.86e-07 Ω·m normalized or normalized formed (+N) EN 10028-2 Flat -
- 600 °C Electrical resistivity of 7.9e-07 Ω·m normalized or normalized formed (+N) EN 10028-2 Flat -

EN 10028-2 Grade P295GH normalized or normalized formed (+N) mechanical

Property Temperature Value Condition Related Standards Shape Comment
Elastic modulus -100 °C Elastic modulus of 217 GPa normalized or normalized formed (+N) EN 10028-2 Flat -
- 20 °C Elastic modulus of 212 GPa normalized or normalized formed (+N) EN 10028-2 Flat -
- 100 °C Elastic modulus of 207 - 208 GPa normalized or normalized formed (+N) EN 10028-2 Flat -
- 100 °C Elastic modulus of 207 GPa normalized or normalized formed (+N) EN 10028-2 Flat -
- 100 °C Elastic modulus of 208 GPa normalized or normalized formed (+N) EN 10028-2 Flat -
- 200 °C Elastic modulus of 199 - 201 GPa normalized or normalized formed (+N) EN 10028-2 Flat -
- 200 °C Elastic modulus of 199 GPa normalized or normalized formed (+N) EN 10028-2 Flat -
- 200 °C Elastic modulus of 201 GPa normalized or normalized formed (+N) EN 10028-2 Flat -
- 300 °C Elastic modulus of 192 - 193 GPa normalized or normalized formed (+N) EN 10028-2 Flat -
- 300 °C Elastic modulus of 192 GPa normalized or normalized formed (+N) EN 10028-2 Flat -
- 300 °C Elastic modulus of 193 GPa normalized or normalized formed (+N) EN 10028-2 Flat -
- 400 °C Elastic modulus of 184 - 185 GPa normalized or normalized formed (+N) EN 10028-2 Flat -
- 400 °C Elastic modulus of 184 GPa normalized or normalized formed (+N) EN 10028-2 Flat -
- 400 °C Elastic modulus of 185 GPa normalized or normalized formed (+N) EN 10028-2 Flat -
- 500 °C Elastic modulus of 175 GPa normalized or normalized formed (+N) EN 10028-2 Flat -
- 600 °C Elastic modulus of 164 GPa normalized or normalized formed (+N) EN 10028-2 Flat -
Elongation - Elongation of 15.4 % - - - Predicted Value, A200
- - Elongation of 15.7 % - - - Predicted Value, A80
- - Elongation of 16.6 % - - - Predicted Value, A80 Transverse
- - Elongation of 16.8 % - - - Predicted Value, A5
- - Elongation of 19.2 % - - - Predicted Value, A50
- 20 °C Elongation of 21 % normalized or normalized formed (+N) EN 10028-2 Flat Transverse
- 20 °C Elongation of 21 % normalized or normalized formed (+N) EN 10028-2 Flat -
Hardness, Brinell - Hardness, Brinell of 244 [-] - - - Predicted Value, Transverse
Poisson's ratio - Poisson's ratio of 0.29 [-] - - - Typical for Low Carbon Steel
Reduction of area - Reduction of area of 42.0 % - - - Predicted Value
- - Reduction of area of 43.5 % - - - Predicted Value, Transverse
Shear modulus - Shear modulus of 82 GPa - - - Typical for Low Carbon Steel
Shear strength - Shear strength of 547.7 MPa - - - Predicted Value
Tensile strength 20 °C Tensile strength of 430 - 580 MPa normalized or normalized formed (+N) EN 10028-2 Flat Transverse
- 20 °C Tensile strength of 430 - 570 MPa normalized or normalized formed (+N) EN 10028-2 Flat Transverse
- 20 °C Tensile strength of 430 - 580 MPa normalized or normalized formed (+N) EN 10028-2 Flat -
- 20 °C Tensile strength of 430 - 570 MPa normalized or normalized formed (+N) EN 10028-2 Flat -
- 20 °C Tensile strength of 440 - 580 MPa normalized or normalized formed (+N) EN 10028-2 Flat Transverse
- 20 °C Tensile strength of 440 - 570 MPa normalized or normalized formed (+N) EN 10028-2 Flat Transverse
- 20 °C Tensile strength of 440 - 580 MPa normalized or normalized formed (+N) EN 10028-2 Flat -
- 20 °C Tensile strength of 440 - 570 MPa normalized or normalized formed (+N) EN 10028-2 Flat -
- 20 °C Tensile strength of 460 - 580 MPa normalized or normalized formed (+N) EN 10028-2 Flat Transverse
- 20 °C Tensile strength of 460 - 570 MPa normalized or normalized formed (+N) EN 10028-2 Flat Transverse
- 20 °C Tensile strength of 460 - 580 MPa normalized or normalized formed (+N) EN 10028-2 Flat -
- 20 °C Tensile strength of 460 - 570 MPa normalized or normalized formed (+N) EN 10028-2 Flat -
Yield strength - Yield strength of 289.1 MPa - - - Predicted Value, RP1 Transverse
- - Yield strength of 299.4 MPa - - - Predicted Value, RP1
- - Yield strength of 378.1 MPa - - - Predicted Value, RP05
- - Yield strength of 407.3 MPa - - - Predicted Value, RP02 Transverse
- - Yield strength of 601.7 MPa - - - Predicted Value, RP002
- 20 °C Yield strength of 220 MPa normalized or normalized formed (+N) EN 10028-2 Flat Transverse
- 20 °C Yield strength of 220 MPa normalized or normalized formed (+N) EN 10028-2 Flat -
- 20 °C Yield strength of 235 MPa normalized or normalized formed (+N) EN 10028-2 Flat Transverse
- 20 °C Yield strength of 235 MPa normalized or normalized formed (+N) EN 10028-2 Flat -
- 20 °C Yield strength of 260 MPa normalized or normalized formed (+N) EN 10028-2 Flat Transverse
- 20 °C Yield strength of 260 MPa normalized or normalized formed (+N) EN 10028-2 Flat -
- 20 °C Yield strength of 285 MPa normalized or normalized formed (+N) EN 10028-2 Flat Transverse
- 20 °C Yield strength of 285 MPa normalized or normalized formed (+N) EN 10028-2 Flat -
- 20 °C Yield strength of 290 MPa normalized or normalized formed (+N) EN 10028-2 Flat Transverse
- 20 °C Yield strength of 290 MPa normalized or normalized formed (+N) EN 10028-2 Flat -
- 20 °C Yield strength of 295 MPa normalized or normalized formed (+N) EN 10028-2 Flat Transverse
- 20 °C Yield strength of 295 MPa normalized or normalized formed (+N) EN 10028-2 Flat -
- 50 °C Yield strength of 213 MPa normalized or normalized formed (+N) EN 10028-2 Flat RP02
- 50 °C Yield strength of 227 MPa normalized or normalized formed (+N) EN 10028-2 Flat RP02
- 50 °C Yield strength of 251 MPa normalized or normalized formed (+N) EN 10028-2 Flat RP02
- 50 °C Yield strength of 276 MPa normalized or normalized formed (+N) EN 10028-2 Flat RP02
- 50 °C Yield strength of 280 MPa normalized or normalized formed (+N) EN 10028-2 Flat RP02
- 50 °C Yield strength of 285 MPa normalized or normalized formed (+N) EN 10028-2 Flat RP02
- 100 °C Yield strength of 200 MPa normalized or normalized formed (+N) EN 10028-2 Flat RP02
- 100 °C Yield strength of 214 MPa normalized or normalized formed (+N) EN 10028-2 Flat RP02
- 100 °C Yield strength of 237 MPa normalized or normalized formed (+N) EN 10028-2 Flat RP02
- 100 °C Yield strength of 259 MPa normalized or normalized formed (+N) EN 10028-2 Flat RP02
- 100 °C Yield strength of 264 MPa normalized or normalized formed (+N) EN 10028-2 Flat RP02
- 100 °C Yield strength of 268 MPa normalized or normalized formed (+N) EN 10028-2 Flat RP02
- 150 °C Yield strength of 185 MPa normalized or normalized formed (+N) EN 10028-2 Flat RP02
- 150 °C Yield strength of 198 MPa normalized or normalized formed (+N) EN 10028-2 Flat RP02
- 150 °C Yield strength of 219 MPa normalized or normalized formed (+N) EN 10028-2 Flat RP02
- 150 °C Yield strength of 240 MPa normalized or normalized formed (+N) EN 10028-2 Flat RP02
- 150 °C Yield strength of 244 MPa normalized or normalized formed (+N) EN 10028-2 Flat RP02
- 150 °C Yield strength of 249 MPa normalized or normalized formed (+N) EN 10028-2 Flat RP02
- 200 °C Yield strength of 170 MPa normalized or normalized formed (+N) EN 10028-2 Flat RP02
- 200 °C Yield strength of 182 MPa normalized or normalized formed (+N) EN 10028-2 Flat RP02
- 200 °C Yield strength of 201 MPa normalized or normalized formed (+N) EN 10028-2 Flat RP02
- 200 °C Yield strength of 221 MPa normalized or normalized formed (+N) EN 10028-2 Flat RP02
- 200 °C Yield strength of 225 MPa normalized or normalized formed (+N) EN 10028-2 Flat RP02
- 200 °C Yield strength of 228 MPa normalized or normalized formed (+N) EN 10028-2 Flat RP02
- 250 °C Yield strength of 156 MPa normalized or normalized formed (+N) EN 10028-2 Flat RP02
- 250 °C Yield strength of 167 MPa normalized or normalized formed (+N) EN 10028-2 Flat RP02
- 250 °C Yield strength of 184 MPa normalized or normalized formed (+N) EN 10028-2 Flat RP02
- 250 °C Yield strength of 202 MPa normalized or normalized formed (+N) EN 10028-2 Flat RP02
- 250 °C Yield strength of 206 MPa normalized or normalized formed (+N) EN 10028-2 Flat RP02
- 250 °C Yield strength of 209 MPa normalized or normalized formed (+N) EN 10028-2 Flat RP02
- 300 °C Yield strength of 144 MPa normalized or normalized formed (+N) EN 10028-2 Flat RP02
- 300 °C Yield strength of 153 MPa normalized or normalized formed (+N) EN 10028-2 Flat RP02
- 300 °C Yield strength of 170 MPa normalized or normalized formed (+N) EN 10028-2 Flat RP02
- 300 °C Yield strength of 186 MPa normalized or normalized formed (+N) EN 10028-2 Flat RP02
- 300 °C Yield strength of 189 MPa normalized or normalized formed (+N) EN 10028-2 Flat RP02
- 300 °C Yield strength of 192 MPa normalized or normalized formed (+N) EN 10028-2 Flat RP02
- 350 °C Yield strength of 133 MPa normalized or normalized formed (+N) EN 10028-2 Flat RP02
- 350 °C Yield strength of 142 MPa normalized or normalized formed (+N) EN 10028-2 Flat RP02
- 350 °C Yield strength of 157 MPa normalized or normalized formed (+N) EN 10028-2 Flat RP02
- 350 °C Yield strength of 172 MPa normalized or normalized formed (+N) EN 10028-2 Flat RP02
- 350 °C Yield strength of 175 MPa normalized or normalized formed (+N) EN 10028-2 Flat RP02
- 350 °C Yield strength of 178 MPa normalized or normalized formed (+N) EN 10028-2 Flat RP02
- 400 °C Yield strength of 125 MPa normalized or normalized formed (+N) EN 10028-2 Flat RP02
- 400 °C Yield strength of 133 MPa normalized or normalized formed (+N) EN 10028-2 Flat RP02
- 400 °C Yield strength of 148 MPa normalized or normalized formed (+N) EN 10028-2 Flat RP02
- 400 °C Yield strength of 162 MPa normalized or normalized formed (+N) EN 10028-2 Flat RP02
- 400 °C Yield strength of 165 MPa normalized or normalized formed (+N) EN 10028-2 Flat RP02
- 400 °C Yield strength of 167 MPa normalized or normalized formed (+N) EN 10028-2 Flat RP02

Have confidence in the strength and durability of our steel materials.

-- Our promise

Similar or equivalent steel materials

Get a quote