Charpy impact energy, V-notch |
-40 °C |
Charpy impact energy, V-notch of 40 J |
min., average |
Charpy impact energy, V-notch, transverse |
-40 °C |
Charpy impact energy, V-notch, transverse of 27 J |
min., average |
Creep strength 10^4 cycles |
400 °C |
Creep strength 10^4 cycles of 380 MPa |
1% creep strain, Larson Miller method, up to 33 000 hours, 10^4 cycles |
- |
410 °C |
Creep strength 10^4 cycles of 360 MPa |
1% creep strain, Larson Miller method, up to 33 000 hours, 10^4 cycles |
- |
420 °C |
Creep strength 10^4 cycles of 355 MPa |
1% creep strain, Larson Miller method, up to 33 000 hours, 10^4 cycles |
- |
430 °C |
Creep strength 10^4 cycles of 339 MPa |
1% creep strain, Larson Miller method, up to 33 000 hours, 10^4 cycles |
- |
440 °C |
Creep strength 10^4 cycles of 323 MPa |
1% creep strain, Larson Miller method, up to 33 000 hours, 10^4 cycles |
- |
450 °C |
Creep strength 10^4 cycles of 305 MPa |
1% creep strain, Larson Miller method, up to 33 000 hours, 10^4 cycles |
- |
460 °C |
Creep strength 10^4 cycles of 287 MPa |
1% creep strain, Larson Miller method, up to 33 000 hours, 10^4 cycles |
- |
470 °C |
Creep strength 10^4 cycles of 267 MPa |
1% creep strain, Larson Miller method, up to 33 000 hours, 10^4 cycles |
- |
480 °C |
Creep strength 10^4 cycles of 247 MPa |
1% creep strain, Larson Miller method, up to 33 000 hours, 10^4 cycles |
- |
490 °C |
Creep strength 10^4 cycles of 226 MPa |
1% creep strain, Larson Miller method, up to 33 000 hours, 10^4 cycles |
- |
500 °C |
Creep strength 10^4 cycles of 204 MPa |
1% creep strain, Larson Miller method, up to 33 000 hours, 10^4 cycles |
- |
510 °C |
Creep strength 10^4 cycles of 180 MPa |
1% creep strain, Larson Miller method, up to 33 000 hours, 10^4 cycles |
- |
520 °C |
Creep strength 10^4 cycles of 156 MPa |
1% creep strain, Larson Miller method, up to 33 000 hours, 10^4 cycles |
- |
530 °C |
Creep strength 10^4 cycles of 131 MPa |
1% creep strain, Larson Miller method, up to 33 000 hours, 10^4 cycles |
- |
540 °C |
Creep strength 10^4 cycles of 105 MPa |
1% creep strain, Larson Miller method, up to 33 000 hours, 10^4 cycles |
- |
550 °C |
Creep strength 10^4 cycles of 78 MPa |
1% creep strain, Larson Miller method, up to 33 000 hours, 10^4 cycles |
Creep strength 10^5 cycles |
400 °C |
Creep strength 10^5 cycles of 330 MPa |
1% creep strain, Larson Miller method, up to 33 000 hours, 10^5 cycles |
- |
410 °C |
Creep strength 10^5 cycles of 312 MPa |
1% creep strain, Larson Miller method, up to 33 000 hours, 10^5 cycles |
- |
420 °C |
Creep strength 10^5 cycles of 293 MPa |
1% creep strain, Larson Miller method, up to 33 000 hours, 10^5 cycles |
- |
430 °C |
Creep strength 10^5 cycles of 274 MPa |
1% creep strain, Larson Miller method, up to 33 000 hours, 10^5 cycles |
- |
440 °C |
Creep strength 10^5 cycles of 253 MPa |
1% creep strain, Larson Miller method, up to 33 000 hours, 10^5 cycles |
- |
450 °C |
Creep strength 10^5 cycles of 231 MPa |
1% creep strain, Larson Miller method, up to 33 000 hours, 10^5 cycles |
- |
460 °C |
Creep strength 10^5 cycles of 208 MPa |
1% creep strain, Larson Miller method, up to 33 000 hours, 10^5 cycles |
- |
470 °C |
Creep strength 10^5 cycles of 184 MPa |
1% creep strain, Larson Miller method, up to 33 000 hours, 10^5 cycles |
- |
480 °C |
Creep strength 10^5 cycles of 159 MPa |
1% creep strain, Larson Miller method, up to 33 000 hours, 10^5 cycles |
- |
490 °C |
Creep strength 10^5 cycles of 133 MPa |
1% creep strain, Larson Miller method, up to 33 000 hours, 10^5 cycles |
- |
500 °C |
Creep strength 10^5 cycles of 106 MPa |
1% creep strain, Larson Miller method, up to 33 000 hours, 10^5 cycles |
Tensile strength |
23 °C |
Tensile strength of 500 - 660 MPa |
transverse test speciemen, thickness ≤ 100mm |
- |
100 °C |
Tensile strength of 310 - 335 MPa |
transverse test speciemen, thickness ≤ 100mm |
- |
200 °C |
Tensile strength of 310 - 335 MPa |
transverse test speciemen, thickness ≤ 100mm |
- |
300 °C |
Tensile strength of 275 - 295 MPa |
transverse test speciemen, thickness ≤ 100mm |
- |
400 °C |
Tensile strength of 250 - 275 MPa |
transverse test speciemen, thickness ≤ 100mm |
- |
500 °C |
Tensile strength of 235 - 250 MPa |
transverse test speciemen, thickness ≤ 100mm |
Yield strength |
- |
Yield strength of 390 - 420 MPa |
ReH, min. values depending on the thickness, If not apparent, the yield strength Rp0.2 is measured |
Get a quote